Filters
Question type

What is a service drop?

Correct Answer

verifed

verified

A service drop is the overhead...

View Answer

A 4 AWG bare copper conductor at least 20 ft (6.0 m) long installed identically to the steel reinforcing rod is also permitted as a concrete-encased grounding electrode. This is often referred to as a(n) ____________________ ground.

Correct Answer

verifed

verified

An exterior raceway containing service entrance conductors must be ____________________ and arranged to drain.

Correct Answer

verifed

verified

It is extremely important that a disconnect or panelboard used as service equipment be marked "____________________."

Correct Answer

verifed

verified

Suitable f...

View Answer

For a one-family residence, the minimum size main service disconnecting means is ____ three-wire.


A) 30-ampere
B) 60-ampere
C) 100-ampere
D) 150-ampere

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Ground rods must be at least ____ ft. in length


A) 6
B) 8
C) 10
D) 12

E) A) and D)
F) A) and C)

Correct Answer

verifed

verified

B

Ground clamps used for bonding and grounding must be ____.


A) approved
B) copper
C) steel
D) listed for the purpose

E) A) and B)
F) All of the above

Correct Answer

verifed

verified

If extra support is not to be provided, the mast service conduit must be at least ____ in. in diameter.


A) 1
B) 1-1/2
C) 2
D) 2-1/2

E) A) and B)
F) B) and C)

Correct Answer

verifed

verified

A panelboard must not be installed in a(n) ____________________.

Correct Answer

verifed

verified

NEC 300.4(F) states that if ____ AWG or larger ungrounded circuit conductors enter a cabinet, box enclosure or raceway, an insulating bushing or equivalent must be used.


A) 4
B) 6
C) 8
D) 10

E) A) and B)
F) C) and D)

Correct Answer

verifed

verified

A

Under no circumstances shall the service entrance conductors be less than ____ ft. above finished grade.


A) 6
B) 8
C) 10
D) 12

E) B) and D)
F) B) and C)

Correct Answer

verifed

verified

When using a metal water pipe as a grounding electrode, a(n) ____________________ is required.

Correct Answer

verifed

verified

supplemental electrode

Using an electric rate of $0.07824 per kWh, calculate the cost of running ten 100W lamps for six hours.

Correct Answer

verifed

verified

Cost = watts × hours...

View Answer

A main service disconnect shall not be installed in a ____.


A) bedroom
B) laundry room
C) garage
D) bathroom

E) A) and B)
F) B) and D)

Correct Answer

verifed

verified

NEC ____________________ provides rules for working space around electrical equipment.

Correct Answer

verifed

verified

____________________ conductors are permitted to be attached to and supported by the service mast.

Correct Answer

verifed

verified

Bonding at service-entrance equipment is very important because service-entrance conductors do not have ____________________ at their line side, other than the electric utility company's primary transformer fuses.

Correct Answer

verifed

verified

overcurren...

View Answer

A working space not less than ____ in. wide and 3 ft deep must be provided in front of electrical equipment, such as panelboards A and B in this residence.


A) 16
B) 24
C) 30
D) 36

E) A) and B)
F) B) and D)

Correct Answer

verifed

verified

For typical residential wiring, the grounding electrode conductor is run between the ____________________ neutral/ground terminal bar and the grounding electrode system.

Correct Answer

verifed

verified

What are service lateral conductors?

Correct Answer

verifed

verified

If installed by the electric u...

View Answer